Calculators

Find out what heat pump your home actually needs

In today’s world of smart meters, smart thermostats and freely available weather data, it’s remarkable that most heat loss assessors still ignore the one source of data that shows exactly how much heat your building lost last winter. This calculator uses your real energy data — not lookup tables and assumptions — to estimate your home’s actual heat loss.

If you’re not sure where to find the numbers, drop me an email and I’ll help. So don’t worry if it looks a bit confusing!

🌿 Heat Loss Calculator

Find your home's true heat demand — and the right heat pump size

Your heating pattern
Think back to the coldest days last winter. What temperatures did you keep your home at? Being accurate here makes the biggest difference to the result.
20°C
The temperature your thermostat was set to when you were home and active. Typically 19–21°C.
16°C
The temperature overnight or while out. Typically 14–17°C. If you heat continuously, set this the same as above.
14 hrs
Count the total hours the boiler was actively running to maintain your set-point. Example: 7am–9am + 4pm–10pm = 10 hours. All-day heating = 24 hours.
Your gas consumption
Choose the best method for the data you have. A reading from a genuinely cold day gives the most accurate heat pump sizing — but an annual bill works well too.
In your energy app, open the hourly view for a cold winter day. Find a block of 3–6 hours starting at least 2 hours after your boiler first came on — this avoids the warm-up spike. Add up the kWh for those hours and enter the total here.
4 hrs
The number of hours you're using from the steady-state period. Longer windows give more accurate averages.
3°C
Check your weather app history for that date and time. The outdoor temperature during your chosen window is important — even a rough estimate helps.
Check your smart meter app — most show daily gas use in kWh. If your meter reads in m³ we'll convert automatically (1 m³ ≈ 11.1 kWh).
-2°C
Check your weather app's history for that date. London's coldest winter days are typically −5°C to +2°C. If unsure: use −2°C for a very cold day, 0°C for a moderately cold day.
Find this on your annual energy statement or from 12 months of meter readings. An average UK home uses 11,000–15,000 kWh/year for gas.
Used to estimate how much gas goes to hot water versus space heating.
Your boiler
Boiler efficiency determines how much of the gas you burn actually becomes useful heat. This is critical for converting your gas consumption into a true heat loss figure.
Not sure? If you can see a white plastic flue pipe going through an outside wall (rather than up through the roof), it's likely a condensing boiler. Models installed after April 2005 must be condensing by law.
21°C
The MCS design standard uses 21°C — the indoor temperature the heat pump must maintain when the outside is at the design temperature of −1.7°C (London and South East England).
Your design heat loss
—
kW at −1.7°C (London / SE England design temperature)

Recommended HP size
—
—
Heat loss coefficient
—
W per °C temperature difference
Est. annual HP electricity
—
kWh/yr — assumes seasonal COP 3.0
Data source
—
—
Confidence in result—
How we calculated this
Important notes on accuracy

This estimate is based on your measured gas consumption and a simplified steady-state heat loss model. It does not account for thermal mass effects, solar gain, airtightness variations, or occupancy patterns. The annual bill method assumes average London heating degree days (2,050 HDD, base 15.5°C). For a precise, MCS 3005-compliant calculation — including correct treatment of party walls in terraced and semi-detached homes — a professional heat loss survey is recommended before purchasing any equipment.

Want a precise, MCS-compliant result?

A full heat loss survey includes room-by-room measurement and correct party wall treatment for pre-1965 terraced and semi-detached homes. I can point you to an installer I trust to do one properly.